- Quality of the measurement data is high.
- Origin of the data is Ascend Acoustics.
- Format of the data is a set of 36 horizontal and 36 vertical measurements .
-
Sensitivity:
- Company: 88.0 dB
- Measured: 87.5 dB (avg. 300Hz-3kHz for 2.83V measured at 1m).
- -3dB (resp. -6db) point v.s. reference is at 51.3Hz (resp. 36.6Hz).
- Reference level is normalised to -0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 1.9dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 5.48
and would be 7.14 with a
perfect subwoofer.
- Details: NBD: ON 0.378, LW 0.322, SP 0.388, PIR 0.319; SM: SP0.503, PIR0.585; LFQ 1.364, LFX 35Hz
- Tonality (Preference) Score is 6.52
with an EQ and would be 7.74 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.302, LW 0.264, SP 0.328, PIR 0.26; SM: SP0.55, PIR0.685; LFQ 1.192, LFX 27Hz
- Tonality (Preference) Score is 5.48
and would be 7.14 with a
perfect subwoofer.